IFM Efector PN2228 Pressure Sensor with Display PN-,25-RBN14-MFRKG/US/ /V
Brand: IFM Efector | Model: PN2228 | Condition: New | NEO SKU: 10952-2
Out of stock
Request for Quote
NEO SKU: 10952-2 | Category: Pressure Sensors
IFM Efector PN2228 Pressure Sensor with Display PN-,25-RBN14-MFRKG/US/ /V
Product Details:
Related Products
Additional information
Weight | 3 lbs |
---|---|
Dimensions | 8 × 8 × 7 in |
Brand | |
Model | PN2228 |
Origin | Germany |
Condition | New |
IFM Efector PN2228 Pressure Sensor with Display PN-,25-RBN14-MFRKG/US/ /V
Specifications:
SKU: 10952-2
Condition: New Surplus Manufacturer Packaging
Brand: IFM Efector
Model: PN2228
Description: Pressure Sensor with Display PN-,25-RBN14-MFRKG/US/ /V
Origin: Germany
Notes: Two switching outputs, one of them programmable as analog output
Clearly visible numerical display
Country-specific pressure units selectable
With long-term stability thanks to high overload protection
Selectable output polarity
Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Measuring range [inH2O]
-5…100.4
Process connection
threaded connection 1/4″ NPT Internal thread
Application
System
gold-plated contacts
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25…80
Min. bursting pressure [inH2O]
12000
Pressure rating [inH2O]
2400
Type of pressure
relative pressure
Electrical data
Operating voltage [V]
18…32 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analog signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / closed; (configurable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
250
Switching frequency DC [Hz]
< 500
Number of analog outputs
1
Analog current output [mA]
4...20; (scalable 1:4)
Max. load [Ω]
(Ub - 10 V) / 20 mA
Analog voltage output [V]
0...10; (scalable 1:4)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit protection
yes (non-latching)
Overload protection
yes
Measuring/setting range
Measuring range [inH2O]
-5...100.4
Set point SP [inH2O]
-4.2...100.4
Reset point rP [inH2O]
-4.6...100
Analog start point [inH2O]
-5...75.4
Analog end point [inH2O]
20.2...100.4
In steps of [inH2O]
0.2
Factory setting
SP1 = 635 mmWS
rP1 = 585 mmWS
SP2 = 1910 mmWS
rP2 = 1860 mmWS
ASP = 0.00 mmWS
AEP = 2550 mmWS
Accuracy / deviations
Switch point accuracy [% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]
< ± 0,2; (0...80 °C)
Reaction times
Response time [ms]
< 1.5
Damping process value dAP [s]
0.01...4
Damping for the analog output dAA [s]
0.01...4
Max. response time analog output [ms]
3
Software / programming
Parameter setting options
hysteresis / window; normally open / closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; Zero point; span
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.0
Operating conditions
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 65
Tests / approvals
EMC
EN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
10 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-5 Surge
0,5/1 kV
EN 61000-4-6 HF conducted
10 V
Shock resistance
DIN IEC 68-2-27
50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6
20 g (10...2000 Hz)
MTTF [years]
131
Pressure equipment directive
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]
267.5
Material
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts)
stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles
100 million
Process connection
threaded connection 1/4" NPT Internal thread
Restrictor element integrated
no (can be retrofitted)
Displays / operating elements
Display
Display unit
4 x LED, green
Switching status
2 x LED, yellow
Function display
alphanumeric display, 4-digit
Measured values
alphanumeric display, 4-digit
Display unit
mbar; kPa; inH2O; mmWS
Remarks
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with IFM Efector or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
We do our best to get all the information in this listing correct. If you see an error or have any questions, please contact us.
FAQ’s
Looking for a replacement IFM Efector PN2228 with fast shipping?
NEO Surplus will ship in stock items the same day if purchased by 2pm ET, Monday – Friday.
What is the HP rating for IFM Efector PN2228?
HP:
NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with IFM Efector or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
NEO Surplus buys surplus MRO items and then resells them on the secondary parts markets.
We do our best to get all the information in this listing correct. If you have any questions or see an error, please contact us.